Cleaning the Air Clamp Rail: CMC Models with Air Clamp Rails

We are experiencing technical issues with the Knowledge Base at this time
If you are missing information, please contact us at 888-855-3335

Cleaning the Air Clamp Rail: CMC Models with Air Clamp Rails

  • Debris has a chance to build up behind the Air Clamps on the CMC 5000, 8000 and 8500 models.

  • The debris will eventually bow the Air Clamps out of the Air Clamp Rail.

  • This is apparent if the customer places a piece of matboard into the lower Air Clamp Rail and slides it to the left, and the Air Clamp begins to bind up.

AirClampBlack800.png
Air Clamp
  • Remove the Air Clamp Rail.

airclmp1l800.png
Remove the Air Clamp
  • Clean out the debris.

  • Never use sharp instruments to clean out the Air Clamps or the Air Clamp Rails.

29570b56-6465-4c91-b0af-d0798b7f3296.png
Clean out the Debris
  • Replace the Air Clamp and the Air Clamp Rail.

airclmp2l800.png
Replace the Air Clamp and Air Clamp Rail