nameEclipseChangingTheCartridgeHolderFootBlocks2024-02-29.pdf

Replacing the Left 90° Cartridge Footblock

  • Use the Footblock Tool to remove the current 90° Cartridge Footblock.

Image Removed
Image Added
  • Use the Footblock Tool to remove the current 90° Cartridge Footblock, turning it counter-clockwise half a turn to loosen it.

Image Removed
Image Added
  • Pull the current 90° Cartridge Footblock tool out from the Trolley.

Image Removed
Image Added
  • Place the new 90° Cartridge Footblock tool into the Trolley.

Image Removed
Image Added
  • Use the Footblock Tool to secure the current 90° Cartridge Footblock into place, turning it clockwise half a turn to tighten it. The tool is now ready to be used.

Image Removed
Image Added

Replacing the Right 45°+ Cartridge Footblock

  • Use the Footblock Tool to remove the current 45°+ Cartridge Footblock.

Image Removed
Image Added
  • Use the Footblock Tool to remove the current 45°+ Cartridge Footblock, turning it counter-clockwise half a turn to loosen it.

Image Removed
Image Added
  • Remove the current 45°+ Cartridge Footblock from the Trolley.

Image Removed
Image Added
  • Place the new 45°+ Cartridge Footblock into the Trolley.

  • Use the Footblock Tool to secure the current Cartridge Footblock into place, turning it clockwise half a turn to tighten it. The tool is now ready to be used.

Image Removed
Image Added