Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Tangent Threshold: Cutting Default Setting

Info
  • The Tangent Threshold is the number of degrees between arc segments before the Head will pick up and replunge. 

  • For instance, if the Tangent Threshold is set to 6, anything larger than 6 degrees will cause the Head to pick up and replunge between segments. 

  • The default is 6°.

  • Set the desired default Tangent Threshold.

Panel
panelIconId1f9d9-200d-2642-fe0f
panelIcon:man_mage:
panelIconText🧙‍♂️
bgColor#FFFAE6
Expand
titleTangent Threshold Definition
  • The Tangent Threshold will smooth the connection between the arc circuits that are below the specified Angle Degree in the Tangent Threshold field to provide a smoother cutting transition between the arcs.

  • The more tangent the connection between arcs, the smoother the cut.

  • Any arc connections above the specified Angle Degree in the Tangent Threshold field will cause the head to pick up and replunge.

  • 6° is the standard setting.

TangentDefinition70800.png
Image RemovedImage Added