Info |
---|
The Tangent Threshold is the number of degrees between arc segments before the Head will pick up and replunge. For instance, if the Tangent Threshold is set to 6, anything larger than 6 degrees will cause the Head to pick up and replunge between segments. The default is 6°.
|
Panel |
---|
panelIconId | 1f9d9-200d-2642-fe0f |
---|
panelIcon | :man_mage: |
---|
panelIconText | 🧙♂️ |
---|
bgColor | #FFFAE6 |
---|
| |
Expand |
---|
title | Tangent Threshold Definition |
---|
| The Tangent Threshold will smooth the connection between the arc circuits that are below the specified Angle Degree in the Tangent Threshold field to provide a smoother cutting transition between the arcs. The more tangent the connection between arcs, the smoother the cut. Any arc connections above the specified Angle Degree in the Tangent Threshold field will cause the head to pick up and replunge. 6° is the standard setting.
|
| Image RemovedImage Added |