Change to the 45 Plus Degree Blade Cartridge

  • The 45°+ black metal blade cartridge* is labeled + on the end.

*Older systems may have a 45°+ yellow plastic cartridge. 

  • Push blade cartridge release down to eject the current blade cartridge.

  • Turn 45 Plus degree cartridge over and reinsert into the head with the blade facing the CMC board and the notch on the back of the cartridge facing the head, until it clicks into place. It can only be inserted one way.

  • Turn cartridge over and reinsert into the head with the blade facing the CMC board and the notch on the back of the cartridge facing the head, until it clicks into place. It can only be inserted one way.

  • If there is side-to-side movement of the blade in the blade cartridge, or if chunks have been cut out of it, then it is time to replace the blade cartridge.