  • The 90° blade cartridge is labeled 90° on the end and is green. 

  • Your cartridge may look different from the one pictured, but the steps to change the blade are the same.

  • Push blade cartridge release down to eject the current blade cartridge.

  • Remove the blade from blade cartridge; be careful of the sharp edge.

  • The blade cartridge displays a diagram of the blade orientation (shown in contrast). 

  • Place new blade into cartridge with the longest straight side to the right and the bevel face down, lining up the holes of the blade over the pins in the cartridge.

  • The blade should fit snugly into the recess space provided for it.

  • NOTE: If there is side-to-side movement of the blade in the blade cartridge, or if chunks have been cut out of the cartridge, then it is time to replace the blade cartridge.

  • Turn cartridge over and reinsert into the head with the blade facing the CMC board and the notch on the back of the cartridge facing the head, until it clicks into place. It can only be inserted one way.