Unscrew Air Valve Assembly From the Gantry

Locate the Air Valve Assembly at the top left side of the Gantry by standing in front of the Gantry and looking straight through the wires/Air Lines to the back plate of the Gantry. Locate the two Allen Screws holding the Air Valve Assembly in place.

Image RemovedImage Added

Do not adjust the other two screws on the Air Valve Assembly.

Use a 7/64” Allen wrench T-Handle to remove the screws securing the Air Valve Assembly to the Gantry.

Take note that these screws are tight and may be difficult to remove.
Save the screws.

Unplug Power Plugs

Before unplugging the power plugs, note the position of each one. The bottom one, closest to the back of the Gantry, has a red plastic marker. The middle plug has a clear/white plastic marker, and the top plug has no marker at all.

Unplug each of them by squeezing gently and pulling them straight out from their housing.

Image RemovedImage Added

Disconnect Air Lines

Disconnect the three Air Lines by untwisting the connectors from each other.

Image RemovedImage Added

Disconnect the Air Lines then remove the old Air Valve Assembly carefully from the Gantry.

Image RemovedImage Added

Screw in the Replacement Air Valve Assembly to the Gantry

Take the screws from the old Air Valve Assembly and place them into the new one.

Line up the screws to the screw holes and screw into the back of the Gantry.

It is easier to screw one screw in partially and then the other to ensure proper alignment, then go back and tighten them.

Image RemovedImage Added

Connect Air Line Connectors

Plug in the Air Lines.

Image RemovedImage Added

Matching connector colors.

Image RemovedImage Added

Match airline colors.

Image RemovedImage Added

Plug in Power Plugs

Plug in the Power Plugs. The plug with the red marker gets plugged into the bottom closest to the back of the Gantry.

Image RemovedImage Added

Plug in the plug with the clear/white marker into the top plug.

Image RemovedImage Added

Last Steps

Replace the upper Hood by screwing in the screw that holds it in place. You may have to gently move the Air Lines a bit in order for it to fit snuggly.

Turn on the air source.

Send back the old Air Valve Assembly to Wizard as directed. You are done.