The Air Clamp has begun to leak and needs replacement.
...
View file |
---|
name | AirClampReplacement-AirClampRails2024-05-23.pdf |
---|
|
Air Clamp Replacement |
---|
Place the metal end of the Air Clamp (side without hose) into the slot closest to the end of clamp bar. Push the metal end firmly into clamp bar and tighten the Allen screw. Each Allen screw should have two washers and should be tightened against the flat side of the metal crimp. Grasp the other side of the Air Clamp and stretch until the other metal ring can be inserted into its slot. Push the metal ring into clamp bar and tighten the Allen screw. Each Allen screw should have two washers and should be tightened against the flat side of the metal crimp. While holding the Vertical/Horizontal Clamp near its mounting position, attach the air fitting and lead the air fitting to its pocket. Slip the fitting into its pocket as the clamp is being turned over into its mounting position.
| Image Added |
|
Never use sharp instruments to clean out the Clamps or the Rails.
Image RemovedImage Added |