nameCleaningAirClampRail8500800050002024CleaningAirClampRail-AirClampRails2024-0205-2123.pdf

Air Clamp Cleaning: CMC 5000, 8000 and 8500

Info
  • Debris has a chance to build up behind the Air

Clamp
  • Clamps on the CMC 5000, 8000 and 8500 models.

  • The debris will eventually bow the Air

Clamp
  • Clamps out into the

rail
  • Air Clamp Rail.

  • This is apparent if the customer places a piece of matboard into the lower rail and slides it to the left, and it begins to bind up.

Clean Air Clamp Rail

  • Remove the Air Clamp Rail.

Panel
panelIconId1f9d9-200d-2642-fe0f
panelIcon:man_mage:
panelIconText🧙‍♂️
bgColor#FFFAE6
  • Clean out the debris.

  • Never use sharp instruments to clean out the Clamps or the Rails.