Go back and make sure that the Air Lines on the back of the Board are not pinched between the Board and the Stand. If you have not already done so, reattach the Air Lines on the inside of the Stand Arms to ensure maximum air flow.
Image Removed
Image Added
Connect the Blue Connector from the top of the ST 500 to the Blue Connector/Shut Off Valve of the “Y” Connector.
Connect Red Connector from the top of the Gantry to the Red Connector of “Y” Connector; only one side will fit.
Plug in the Red Air Line Connector from the bottom of the “Y” into the right side of the Air Regulator.
Plug the Air Line coming off the left side of the Air Regulator into your main air supply via 1/4” NPT female connector, or the quick disconnect, whichever type you purchased. Your air compressor should have at least 100 - 120 PSI. It is suggested that Teflon tape be used on the threads of the black fitting to reduce possible air leakage.
Strap your Air Regulator, glass bowl down to the left large wall bracket or left stand side with cable ties provided in your Tool Kit, making sure not to crimp any of the Air Lines.
Connect Blue Connector from the top of the Gantry to the Blue Connector on the back of the Board.
Turn on the Air.
Warning
WARNING: The Air Regulator comes factory-set. Do not make any adjustments to it.
Image RemovedImage Removed
Image AddedImage Added
Continue to Calibration and Alignment of the Straight Line Trimmer.