The Air Clamp has begun to leak and needs replacement.

View file
nameAirClampReplacement8500800050002024AirClampReplacement-InflatingRailClamps2024-0205-2123.pdf

Removing the Air Clamp

Info
  • When an Air Clamp blows/leaks on the CMC 5000, 8000 and 8500, it needs to be replaced.

  • Move the Gantry to the right until it moves no further.

  • Determine which Clamp is leaking.

  • Remove the appropriate Clamp mounting screws with an Allen wrench.

  • Loosen the 7/64” Allen Screw holding the Air Clamp, and gently lift the Vertical/Horizontal Clamp to view the small air hose fitting.

  • Lift fitting from its groove and disconnect it by unscrewing the two halves.

  • Note that the CMC 5000 air fitting is straight, and the CMC 8000/8500 is an elbow fitting.

  • On later machines, simply pull the two hoses apart.

  • Lay the Vertical/Horizontal Clamp upside down to look at its construction.

  • Loosen the two Allen screws at each end of the rubber tube until you can pull the Air Clamp out.

  • The Air Clamp has been removed.

...