The Air Clamp has begun to leak and needs replacement.
View file |
---|
name | AirClampReplacement8500800050002024-02-21.pdf |
---|
|
Air Clamp Removal: CMC 8500, 8000 and 5000 |
---|
When an Air Clamp blows/leaks, it needs to be replaced. Move the Gantry to the right until it moves no further. Determine which Clamp is leaking and remove the appropriate Clamp mounting screws with an Allen wrench.
| |
Loosen the 7/64” Allen Screw holding the Air Clamp, and gently lift Vertical/Horizontal Clamp to view small air hose fitting. Lift fitting from its groove and disconnect it by unscrewing the two halves. Note that the CMC 5000 air fitting is straight, and the CMC 8000/8500 is an elbow fitting. On later machines, simply pull the two hoses apart.
|
|
| |
| |
...