nameVerticalBeltTension800085008500e8500eSBT2021-01-29.pdf

Vertical Belt Tension

Reset the vertical tension if the vertical belt feels loose.

Click Reset Motors to turn off power to the motors.

Image Modified

Manually move the Head to the top of the Gantry and down again. Remove the lower gantry cover by removing the screw holding it in place.

Image Modified

Manually move the head up on the gantry. With an 1/8” Allen wrench, loosen the Vertical Tension Screw on the bottom of the Gantry rail NEAR the screw that holds the Toothed Pulley. You may see the Toothed Pulley spring out downward. Snugly retighten the screw.

Image Modified

Reinstall the gantry cover, replacing the screw you removed earlier.

Image Modified